Aluminium windowsSliding windowsCasement windowsTilt and turn windowsFloor to ceiling windowsDouble glazed windowsuPVC or aluminiumWindow pricesAll guides

Doors and nets

Sliding glass doorsLift and slide doorsBifold doorsEntrance doorsPivot doorsuPVC doorsMosquito net typesFly screen doors

Brands and builders

Window brands ratingSchücoAlumilReynaersAluKDevelopers ratingExpert reviewsArticlesHow we rankAdd company
Guide · UAE · 24 November 2026

Aluminium Doors on Hinges: What the Data Sheets Say

Aluminium doors on hinges usually carry between 120 and 250 kg per leaf. Four Reynaers series and Technal TITANE 65 share the top figure in our table, so weight alone settles nothing. Heat loss from Ud 0.81 to 1.6 W/m²K, rain class and tested openings do the sorting.

What 250 kg on a hinge really means

The figure is the limit of the hinges and the lock side together, and five of the twelve rows below hit it. CS 77, MasterLine 8, MasterLine 10 and EcoSystem 50 all state 250 kg, and Technal prints the same number for TITANE 65 as the glass load of one leaf. Schüco heavy duty models stop at 200, AluK D67 and D77 at 180.

For a house the gap rarely matters. A glazed leaf one metre wide and 2.4 m high with two 6 mm panes holds roughly 72 kg of glass. Add the profile and you are still far below every row. The heavy ratings earn their keep when a leaf grows to 1,400 by 3,000 mm, a limit Schüco HD and TITANE share, or when the infill is stone.

Leave a requestName, number, kind of work
Leave a requestAd

We will suggest a company from the Recommended list, and it will call you.

Aluminium doors: 12 series by heaviest leaf

From 89 series of 13 brands. Figures as published by the makers, the glass and size of each test differ.

#BrandSeriesLeaf, kgLeaf, mmUd, W/m²KDepth, mmIn the UAESource
1ReynaersCS 77250—1.468yessheet
2ReynaersMasterLine 8250—0.9877yessheet
3ReynaersMasterLine 10250—0.8197yessheet
4ReynaersEcoSystem 50250—1.650yessheet
5TechnalTITANE 652501400 × 30000.9565yessheet
6SchücoADS 50.NI2001100 × 2500—50yessheet
7SchücoADS 65 HD2001400 × 3000——yessheet
8SchücoADS 70 HD2001400 × 3000—70yessheet
9SchücoADS 75 HD.HI2001400 × 3000——yessheet
10TechnalSOLEAL Next Double Action Door200——65yessheet
11AluKD671801500 × 30000.9167yessheet
12AluKD771801500 × 30000.8577yessheet

Reading Ud before you compare brands

MasterLine 10 leads on heat with Ud 0.81 W/m²K, and it pays for that with a 97 mm deep frame and 48 mm of triple glass at Ug 0.6. EcoSystem 50 closes the list at 1.6, but its sample door had 24 mm glass at Ug 1.0. Two different panes hide inside one column.

Put the same glass in and the spread shrinks. CS 77 at Ug 1.0 gives 1.4, and so does TITANE 65 when its brochure uses that pane. AluK publishes both versions of D77: 1.21 with double glazing, 0.85 with triple. So the pane moves the result by about a third of a unit, while the step from a 50 mm profile to a 68 mm one is worth around 0.2. Part K caps glazed elements in Dubai villas at 2.1 when windows cover under 40% of the wall, which every row with a published Ud clears.

Rain is where aluminium hinged doors differ most

Water class separates this table far better than weight does. MasterLine 10 is tested to 9A, a pressure of 600 Pa. CS 77 holds 300 Pa, Schüco ADS 65 HD 200 Pa, EcoSystem 50 only 150. AluK D77 is the odd one: C5 for wind, among the best here, and 2B for water, the weakest published.

The reason sits at your feet. Hinged doors cannot hide a tall upstand, because people step over it, and each millimetre taken off the sill costs rain pressure. On a west facing villa entrance with no canopy, pick the higher class and accept a visible rebate. Under a deep porch the flat sill is the sensible trade.

Tested openings: houses and lobbies need different numbers

One million cycles is the top endurance result, stated for CS 77, MasterLine 8 and MasterLine 10, and for TITANE 65 under a 250 kg load. Schüco gives ADS 65 HD class 8 for the same test family. At thirty openings a day a family needs ninety years to reach a million. A lobby with a thousand passes gets there in under three.

That arithmetic says where the money belongs. Villa owners can ignore the heavy duty label and spend on glass. A shop, a clinic or the front of a tower should do the reverse, and look hard at how the hinge is built in. Technal runs a stainless pivot through the TITANE profile and buries the door spring in the top rail, so the hinge cannot be reached from the street.

Aluminium doors without a thermal break

A frame with no thermal break suits rooms that are not cooled on one side only. Schüco describes ADS 50.NI as an economical indoor system, with a 50 mm depth and a class 2 rating for air. It belongs in a partition, a store or a lobby screen.

Put it between a cooled majlis and a July terrace and the inner face warms up, the seals work harder and the room pays. Any leaf to the outside deserves a polyamide break as a starting point. The label to look for is simple: NI or NTB in a series name means the break is absent.

Ordering an aluminium glass door: width and panes

Table K.4 of the Dubai code sets 915 mm as the clear width of a villa entry, and 710 for bathrooms. Clear means measured past the open leaf, so a 915 mm leaf fails the check. Ask for the structural opening, the leaf size and the clear figure as three separate lines on the drawing.

A glazed leaf also falls under the safety rule for critical locations, with class 2 to EN 12600 below 900 mm from the floor. Request the pane marking before installation day. Then confirm the sill type by name, the water class for that exact sill and the side the hinges sit on, since wind should press the leaf into its seals.

Reynaers, ConceptSystem 77 doors, technical info, Reynaers, MasterLine 10 doors, technical info, Technal, TITANE 65 door, Schüco UAE, ADS 65 HD technical data, AluK, D77, REHAU, SYNEGO entrance doors data sheet, Dubai Municipality, Dubai Building Code 2021, Part K

Recommended companies

Find the right rating in two taps

Tell us what you need and where. We open the matching top 10.

1. What do you need?

Questions

Which aluminium door series is the best insulated?

Reynaers MasterLine 10 has the lowest Ud in our table, 0.81 W/m²K, measured with 48 mm triple glass. AluK D77 follows at 0.85 and D67 at 0.91, both with triple panes and a shallower frame.

How much weight can an aluminium hinged door hold?

Most published limits run from 120 to 250 kg per leaf. Reynaers states 250 kg for four hinged series, Schüco heavy duty models 200 kg, and AluK 180 kg for D67 and D77.

Aluminium or uPVC doors for a villa entrance?

Aluminium allows larger leaves: 1,400 by 3,000 mm in several series here. uPVC insulates well but usually stays smaller, with REHAU listing 1,100 by 2,350 mm for its SYNEGO entrance door.

What is the minimum width of a villa entry door in Dubai?

The Dubai Building Code asks for a clear width of at least 915 mm at villa entry doors. The leaf itself must be wider, because the stop and the open leaf take part of the passage.

Do aluminium doors get too hot in summer?

The outer face of a dark leaf gets hot in direct sun. A thermal break slows that heat on its way to the inner face, so the profile matters more than the colour of the paint.