+ Add company
+ Add companyAluminiumWindow repairMosquito netsuPVCSliding doorsGlass partitionsAbu DhabiWindow systemsSoundproof windowsHow we rank

Companies in Dubai

Aluminium and glass companiesAluminium windowsAluminium doorsSliding doorsuPVC windowsWindow repairMosquito netsGlass partitionsShower glassSoundproofing

By emirate

Abu DhabiSharjahAjmanRas Al KhaimahUmm Al QuwainFujairahAl Ain

Windows

Aluminium windowsSliding windowsCasement windowsTilt and turn windowsFloor to ceiling windowsDouble glazed windowsuPVC or aluminiumWindow pricesAll guides

Doors and nets

Sliding glass doorsLift and slide doorsBifold doorsEntrance doorsPivot doorsuPVC doorsMosquito net typesFly screen doors

Brands and builders

Window brands ratingSchücoAlumilReynaersAluKDevelopers ratingExpert reviewsArticlesHow we rankAdd company
Guide · UAE · 24 November 2026

Double Glazed Windows for UAE Homes: 12 Frames Compared

Double glazed windows keep two panes apart with a sealed gap, and in Dubai the coating on those panes matters as much as the gap. Guardian rates a bare 4 mm sheet at 5.8 W/m²K and a coated 6-16-4 unit with argon at 1.0. The frames compared here take glass up to 88 mm.

16 mm gasglass, spacer, glass

Double glazed windows in the table: what 12 frames tell

Reynaers MasterLine 10 leads on pocket depth with 88 mm. Alumil SUPREME S91 follows at 81, then SMARTIA S77 and MasterLine 8 share 72. The last row, Schüco AWS 75.SI+, stops at 61 mm. All twelve series are confirmed for the Emirates, out of 123 thermally broken window series from 14 brands in our data, where the middle value is 44 mm.

Those numbers are far above what an ordinary order needs. A 6-16-4 unit is 26 mm thick, so nearly any modern frame will accept it. The extra room exists for a third pane or a heavy laminated sheet, and the buyer who wants neither can look at other columns first.

Leave a requestName, number, kind of work
Leave a requestAd

We will suggest a company from the Recommended list, and it will call you.

Double glazed windows: 12 series by thickest glass

From 123 series of 14 brands. Figures as published by the makers, the glass and size of each test differ.

#BrandSeriesGlass up to, mmUw, W/m²KRw, dBDepth, mmIn the UAESource
1ReynaersMasterLine 10880.84697yessheet
2AlumilSUPREME S91810.79—91yessheet
3AlumilSMARTIA S77720.954277yessheet
4ReynaersMasterLine 8720.884677yessheet
5TechnalSOLEAL Next 65690.854765yessheet
6TechnalSOLEAL Next 75690.784875yessheet
7SchücoAWS 90.SI+68—4790yessheet
8ReynaersCS 77631.34268yessheet
9AluKC67K620.854967yessheet
10AluKC77K620.88—77yessheet
11SchücoAWS 70.HI62—4880yessheet
12SchücoAWS 75.SI+61—4875yessheet

Double or triple: the same frame, two results

Catalogues print their best figure, and it usually belongs to a triple unit. AluK is open about it. C67K drops to 0.85 W/m²K once three panes are fitted and stays at 1.23 with two. For C77K, a frame 10 mm deeper, the pair is 0.88 and 1.19. Technal gives 1.4 for a small SOLEAL Next 65 window with a 24 mm unit and 0.85 for a taller leaf with three panes.

Two leaders show how the pane hides the frame. MasterLine 10 gets 0.80 at 1.23 × 1.48 m with 48 mm of glass rated 0.6, while S91 gets 0.79 at that size from a weaker unit of 0.7. The better glass lost by a hair, so the frame must have made up the rest. CS 77 looks poor beside them at 1.3, yet its sheet assumes glass of 1.0, close to a real double unit. Compare double glazed windows only when the sheet names unit and dimensions.

For the law, two panes are enough. Dubai caps the finished window at 2.1 for a lightly glazed home and at 1.7 for a facade that is mostly glass. Every figure quoted in this section clears both lines.

Sun first: the second number on the glass sheet

Shading coefficient, or SC, says how much solar heat crosses the pane compared with 3 mm clear float. A villa with modest openings is held to 0.40. ClimaGuard Premium2, a fine insulating coating from Guardian, combines 1.1 for heat with an SC of 0.73, so it fails here while SunGuard SN 70/35 lands exactly on 0.40.

A third pane hardly helps with that. The triple version of SN 70/35 halves conduction from 1.0 to 0.5 and moves SC only from 0.40 to 0.37. Put 45 degrees outside and 25 inside: the drop of 20 degrees pushes 20 watts through each square metre of the first unit and 10 through the second. Suppose 500 watts of sunlight also fall on that metre. With solar factors of 0.35 and 0.32 they bring 175 and 160 watts indoors. The sun outweighs the air by a wide margin, and the coating earns its place before the extra pane does.

Noise: why the thickest pocket is not the quietest

Double panel windows reach 49 dB in this table, and the holder is C67K with a 62 mm pocket. S77 offers ten millimetres more and declares 42 dB. Technal gets 47 and 48 dB from its two SOLEAL Next frames, and the sheet for the 65 version shows how: 88.2 acoustic laminate, a 20 mm gap, then 66.2 laminate.

Glass mass and unequal panes do most of that work. Pilkington lists five levers, from mass and asymmetry to gap width, gas and acoustic interlayer. A frame can only be as good as the unit inside it, so ask which build-up stood in the test chamber.

Weight and depth: the price of a thick unit

Float weighs 2,500 kg to the cubic metre. The 10 mm of glass in a 6-16-4 unit comes to 25 kg on every square metre, and a further 4 mm sheet lifts that to 35. On a leaf of 2 square metres that is 50 against 70 kg before the profile is counted. Declared leaf loads in the table run from 150 kg at AluK to 250 kg for the two heaviest Schüco frames, so hinges are rarely the limit at home size.

Depth is the other cost. The leader pays most: MasterLine 10 is 97 mm deep in the frame and S91 takes 91, while SOLEAL Next 65 holds 69 mm of glass in only 65 mm of profile. Deep frames need a wider reveal, which matters in apartments where the old opening has a fixed stone sill.

Reading an order for double glazing in Dubai

A complete line runs from outside to inside. It gives pane one with the coating name and surface 2, then the gap and the gas, then pane two with its safety class. A figure such as 90 percent argon should match the data sheet used for the U value. If the line says only 24 mm clear, the solar side was never chosen.

Position counts as well. The code notes that a sealed unit conducts more heat when laid horizontally, so a skylight cannot borrow the figure of a wall window. Near the floor the inner sheet also needs a safety class, whichever coating was chosen.

Alumil, SUPREME S91, AluK, C67K, AluK Italy, C67K thermal data, AluK, C77K, Schüco UAE, AWS 75.SI+, Reynaers Middle East, MasterLine 10, Reynaers Middle East, ConceptSystem 77, Alumil, SMARTIA S77, Technal, SOLEAL Next 65 data sheet, Guardian Glass, Digital Glass Selector 2025, Pilkington, Glass Handbook 2014, Dubai Municipality, Dubai Building Code 2021

Recommended companies

Find the right rating in two taps

Tell us what you need and where. We open the matching top 10.

1. What do you need?

Questions

Are double glazed windows worth it in Dubai?

Yes, wherever the room is cooled. Conduction through the glass falls from 5.8 to about 1.0 with a coated unit, and no single clear sheet can bring a complete window down to 2.1.

Double vs triple glazing: which is better for the UAE?

Two coated panes normally satisfy the code. Triple halves conduction in the Guardian data, yet shading moves only from 0.40 to 0.37, and each square metre gains 10 kg if the pane is 4 mm.

What is the best glass thickness for double glazing?

There is no single number. 6-16-4 is a common reference build-up at 26 mm. Busy roads call for laminated panes of unequal thickness, and double glazed windows built that way can pass 40 mm.

Which frame in the table blocks most noise?

AluK C67K declares 49 dB, the top figure of the twelve. Schüco AWS 70.HI, AWS 75.SI+ and Technal SOLEAL Next 75 declare 48. Real rooms score lower than the laboratory.

How do I know the glass will keep heat out?

Read the SC on the data sheet. Up to 0.40 suits a villa whose windows are modest, and a bare claim of low emissivity proves nothing about sun, as the 0.73 of ClimaGuard Premium2 shows.

Read and compare next

Leave a requestName, number, kind of work
Leave a requestAd

We will suggest a company from the Recommended list, and it will call you.