Curtain wall types and series compared for UAE buildings
A curtain wall is a glazed skin hung from the floor slabs, carrying wind and its own weight while the building stands without it. Among the 12 series in the table the best frame Uf is 0.52 W/m²K, the weakest is 1.3, and glass thickness with insulating bars explains most of that gap.
Reading the series table
Technal TENTAL leads with a frame Uf of 0.52, ahead of Reynaers CW 50 at 0.56 and CW 60 at 0.6. The last line, ElementFacade 7, stands at 1.3. Makers print the best variant of a family, so the figure you are offered may be higher. Alumil shows its whole span openly: SMARTIA M7 goes from 1.0 to 2.3 depending on the section.
The same Technal sheet shows why the headline misleads. Put Ug 1.1 glass into it and the finished wall comes to Ucw 1.4, almost three times the frame number. Infill up to 62 mm is what buys 0.52. FWS 50.SI from Schüco goes thicker still at 86 mm, and SlimWall 35 settles for 57 mm to keep its bars narrow. For noise look elsewhere in the table: CW 60 is listed at 55 dB against 43 for TENTAL, so the warmest frame is far from the quietest. Alumil and AluK share the 1.0 to 1.2 band, which is ordinary work for Gulf offices.
Leave a requestName, number, kind of work
Curtain walls: 12 series by lowest Uf
From 79 series of 11 brands. Figures as published by the makers, the glass and size of each test differ.
| # | Brand | Series | Uf, W/m²K | Glass up to, mm | Depth, mm | Visible bar, mm | In the UAE | Source |
|---|---|---|---|---|---|---|---|---|
| 1 | Technal | TENTAL 50 / 60 | 0.52 | 62 | — | 50 | yes | sheet |
| 2 | Reynaers | CW 50 | 0.56 | 60 | 42 | 50 | yes | sheet |
| 3 | Reynaers | CW 60 | 0.6 | 60 | 62.5 | 60 | yes | sheet |
| 4 | Schüco | AOC 75 TI | 0.67 | 70 | — | 75 | yes | sheet |
| 5 | Schüco | FWS 50.SI | 0.7 | 86 | 50 | 50 | yes | sheet |
| 6 | Reynaers | SlimWall 35 | 0.71 | 57 | 88.5 | 35 | yes | sheet |
| 7 | Schüco | AOC 50 TI | 0.71 | 70 | — | 50 | yes | sheet |
| 8 | Schüco | AOC 60 TI | 0.71 | 70 | — | 60 | yes | sheet |
| 9 | Alumil | SMARTIA M7 | 1 | 54 | — | 50 | yes | sheet |
| 10 | AluK | SL50 | 1.1 | 40 | — | 50 | yes | sheet |
| 11 | Alumil | SMARTIA M35 | 1.2 | 54 | — | 35 | yes | sheet |
| 12 | Reynaers | ElementFacade 7 | 1.3 | 63 | 167.9 | 75 | yes | sheet |
Stick or unitised construction
Stick systems arrive as bars. Installers bolt mullions to the slab edge, add transoms, then press the glass in from outside under a plate and cap. It suits villas and low blocks, since small quantities need no factory line, yet quality depends on the crew and the weather. Each joint is sealed outdoors, often in dust, and a supervisor should sign every storey before the caps hide it.
Unitised panels leave the plant complete with glass and seals, then hook onto brackets floor by floor. ElementFacade 7 allows modules of 2,700 by 3,700 mm with 75 mm of visible metal inside. Frames double up wherever two modules meet, and that joint is why the unitised row sits at the bottom for Uf. In exchange the tower closes quickly and no scaffold is needed. The design freezes early, because dies, brackets and slab tolerances are fixed months before the first module leaves the plant.
Structural glazing and its silicone
Structural glazing hides the metal by gluing the pane to a carrier frame, so from the street you see glass and dark joints only. Semi-structural versions keep caps along one direction. Dubai ties this use of silicone to ETAG 002, and the adhesive needs matching approval. Sikasil SG-500, for example, holds ETA-03/0038 with a design stress of 0.14 MPa for dynamic loads.
That figure lets an owner check a drawing. Multiply wind pressure by half the short side and divide by the stress. A pane 1.5 m wide under 2 kPa needs about 11 mm of glued width. If the detail shows six, somebody should explain why. Bonding belongs in a clean workshop, and a broken pane replaced years later deserves that same routine.
Spider glazing for lobbies
Spider glazing drops the frame completely. Toughened panes are drilled, bolted to arms of stainless steel, and the arms sit on posts, glass fins or cables. SADEV makes its S 3000 spider in AISI 316L with one to four arms, which covers edges as well as the middle of a wall.
It looks weightless and behaves like bridge work. Holes are drilled before toughening, so a wrong dimension cannot be corrected on site. Dubai adds that glass used structurally must have redundancy: when one sheet breaks, its neighbours pick up the load. A lobby screen can live with a single skin. An air conditioned office usually calls for something with an insulated frame.
Curtain wall Dubai rules: glass share, wind and fall safety
Dubai looks at the whole façade first. Glass may take 40% of the walls of a home and 60% of most other buildings, shopfronts aside. The allowed U-value follows that share, starting at 2.1 and tightening to 1.7 where glass passes 60%. The shading coefficient falls too and ends at 0.25. Those are totals with frame and spacer, which brings back the 1.4 in the Technal sheet.
Mechanical rules follow. Bars behind double glazing may deflect no more than 1/175 of the pane under design load, and test pressure goes on the weakest spot because corners attract more wind. Panes that reach below 800 mm above a drop of 760 mm have to contain a falling person. Brackets must resist corrosion, and the code bans welded fixings outright.
Air, water and sand tests
Compare pressure, since every maker tests to its own ceiling. Reynaers publishes 1,950 Pa for both air and water on CW 50, alongside the British CWCT sequence at 600 Pa. SMARTIA M7 and TENTAL 60 print RE 1200. Schüco AOC 75 TI shows RE 2550. Any of these beats a façade with no report.
A laboratory wall is clean, and one in Al Quoz is not. Drainage slots fill with sand, caps trap dust, and seals work harder in heat. Ask how a blocked drain will be reached on the tenth floor. Find out as well who stocks the coated glass, because a replacement pane from another batch may show a different tint. For any curtain wall over three storeys, plan the cradle or rope anchors with the roof drawings.
Technal, TENTAL 60 MT product sheet, October 2025, Reynaers Aluminium, ConceptWall 50 technical information, Reynaers Aluminium, ConceptWall brochure, Reynaers Aluminium, ElementFacade 7 brochure, Reynaers Aluminium, SlimWall 35 technical information, Schueco UAE, FWS 50.SI technical data, Schueco UAE, AOC 75 TI technical data, Alumil UAE, SMARTIA M7, Sika, Sikasil SG-500 product data sheet, SADEV, S 3000 glass spider, Dubai Municipality, Dubai Building Code 2021
Recommended companies
Find the right rating in two taps
Tell us what you need and where. We open the matching top 10.
Questions
How does a curtain wall differ from a window wall?
The first passes in front of the slabs and hangs from them. A window wall stands between two floors, so each slab edge stays visible and needs its own cover, insulation and seal.
Which façade system insulates best?
By published frame figures TENTAL 60 at 0.52, then CW 50 at 0.56. With Ug 1.1 glass Technal quotes 1.4 for the complete wall, so judge offers by the total Ucw.
Is structural glazing safe in UAE heat?
The adhesive data allows service from minus 40 to 150 °C. Safety depends on joint width, workshop bonding and a project check of every surface the silicone touches. Keep those records with the building file.
Can a villa have spider glazing?
Yes, usually as an entrance screen or a stair enclosure. Remember that a single skin does little against heat, and redundancy has to be designed in, since one broken sheet may not bring down the rest.
What drives the price of a curtain wall in Dubai?
Glass coating and thickness come first, then panel size, because heavy units need cranes. Unitised work adds engineering and a mock-up but saves scaffold time. Small areas tend to favour stick construction.